Electric Injera baking pans (Mitads) are the most prevalent and energy-intensive appliances used in Ethiopia and encounters bulk amounts of heat loss. However, only few and rarely published research and development were made to improve the thermal efficiency of the system and to quantify the amount of loss accounted. This study aims to make intensive experimental investigation to quantify the amount of heat loss accounted in the system and give the clue for the further research investigation to improve thermal performance of the system. Infrared thermometer was used to measure surface temperature of the bare plate and side and bottom enclosures, while K – type thermocouple was used to measure bottom temperature of clay plate and glass thermometer was used to measure surrounding temperature during Injera baking process. The results of experimental investigation were analytically analyzed and electric Injera baking process was encountered 46.15% heat loss. The value obtained from the analysis lies between the ranges (40 - 50%) of prediction made in previous studies.
Injera; baking pan; heat loss; porous media